WEBVTT

00:00:00.002 --> 00:00:03.744
So sometimes, when running images
through CellCount, not all the

00:00:03.744 --> 00:00:05.953
corners of the grid will be visible.

00:00:06.688 --> 00:00:08.101
So I'm uploading an example here.

00:00:09.298 --> 00:00:13.604
Here we can see the entire 1 mm
grid doesn't fit, and it's not perfectly

00:00:13.614 --> 00:00:15.819
positioned underneath the objective.

00:00:16.665 --> 00:00:21.320
So in this case, since we're using a
microscope camera and the cells actually

00:00:21.320 --> 00:00:25.826
go all the way from edge to edge of the
image, what I would do then, and this

00:00:25.826 --> 00:00:28.851
is actually much better, is to turn
on the full image mode, so it doesn't

00:00:29.054 --> 00:00:30.398
constrain the counting to the grids.

00:00:30.410 --> 00:00:31.626
It uses the entire image.

00:00:31.655 --> 00:00:33.718
And we actually get a
larger counted volume.

00:00:34.153 --> 00:00:37.976
If we look here, we're counting
0.12 microliters.

00:00:38.184 --> 00:00:42.253
If we go back to counting only the grids,
we're at 0.081 microliters.

00:00:42.261 --> 00:00:44.935
So by using the full image, we
actually count more cells, getting

00:00:44.935 --> 00:00:46.640
a better concentration estimate.

00:00:47.093 --> 00:00:49.701
And you can see here we still get
the same cells per milliliter

00:00:49.741 --> 00:00:51.409
and the viability as before.

00:00:52.449 --> 00:00:53.216
So we can click Done.

00:00:54.374 --> 00:00:59.601
And if you consistently use a microscope
camera to do these measurements, then it's

00:00:59.603 --> 00:01:01.481
a good idea to create a protocol for this.

00:01:01.523 --> 00:01:02.935
So switching to protocol.

00:01:03.325 --> 00:01:04.850
Right now, we have no protocol turned on.

00:01:05.070 --> 00:01:07.925
If I create a new protocol, for
example, we can count the whole image.

00:01:08.073 --> 00:01:10.371
So this will just automatically
apply this setting.

00:01:10.525 --> 00:01:11.828
We can do one image at a time.

00:01:12.433 --> 00:01:13.822
We want to report with viability.

00:01:14.393 --> 00:01:16.490
We use a one-to-one dilution
with trypan blue, so let's set

00:01:16.490 --> 00:01:17.627
the dilution factor to two.

00:01:18.173 --> 00:01:20.354
The default sensitivity,
balanced, is fine.

00:01:20.517 --> 00:01:22.741
Open the camera when the
protocol is chosen, that's okay.

00:01:23.441 --> 00:01:25.159
And then apply the detected
grid automatically.

00:01:25.163 --> 00:01:28.994
And then if we go to this
protocol, we can use it, clear

00:01:28.994 --> 00:01:30.182
the sample and start a new one.

00:01:30.453 --> 00:01:33.399
So here it'll give you the option
to upload a file or use the camera.

00:01:34.692 --> 00:01:37.367
You'll see it automatically just finds
two reference points, uses that to

00:01:37.368 --> 00:01:38.595
set the scale for the whole image.

00:01:38.595 --> 00:01:41.088
And it also is nice because you
don't have to worry about positioning

00:01:41.097 --> 00:01:43.602
the slide correctly underneath
to get the whole grid in line.

