Tutorials

CellCount tutorials, in short videos.

Short videos of real counts in CellCount, start to finish: one photo of a hemocytometer counted on a computer, a count on a phone at the eyepiece, and full image mode for a frame where the whole grid does not fit. Each plays here when you press play, and each has its transcript.

Updated

Count cells from one hemocytometer photo

0:40 · · Watch on YouTube · Captions (WebVTT)

One photo of a hemocytometer, taken through the eyepiece with a phone and uploaded on a computer. CellCount finds the grid, sets the scale from it and counts the cells. With trypan blue, one tap on + Viability splits live from dead and gives cells per mL and percent viable. It works with a phone or a microscope camera you already have.

Transcript

Sometimes you have to count cells by hand. So this is how I automate that. I'm taking one photo, and in this case I'll be using a phone capture. I upload it straight into CellCount. It counts the cells right away, detects the grid, and finds the scale. You're mixing it with trypan blue, you can do plus viability. And here you see the live cells are green and the dead ones are red, and then you get your total cells per milliliter along with your percent viable. It works with the phone in your pocket. It also works with a microscope camera that you already have. Try with your own image. The link's in my profile. I hope it helps!

Count cells on your phone

0:42 · · Watch on YouTube · Captions (WebVTT)

A cell count with nothing but a phone and a microscope. CellCount in the phone’s browser picks out the hemocytometer grid, outlines each cell, and with trypan blue mixed one to one splits live from dead. You get cells per mL, percent viability and the cell count, with clumps reported separately.

Transcript

Sometimes you have to count cells by hand, and so I'm going to show you how I automate that. So this is just a phone capture through the eyepiece of a microscope, and we're looking at the hemocytometer grid here, which the CellCount software has picked out the grid, and you can see each cell is outlined as well. If we zoom in, we can see how it finds the cells here and the grids. And the nice thing about this is that we can turn on viability because we're using trypan blue with a one-to-one dilution here. So the dead cells turn red and the green ones are alive. So we get the total cells per milliliter along with the percent viability, number of cells, and it also reports aggregates, like this one. So I hope this helps, and the link's in my bio, so try it out and let me know how it works for you.

Full image mode: count every cell in the frame

1:44 · · Watch on YouTube · Captions (WebVTT)

When the whole 1 mm grid does not fit in the photo and the cells run edge to edge, turn on full image mode. The grid still sets the scale, and every cell in the frame is counted. In the example the counted volume goes from 0.081 µL with the grid squares to 0.12 µL with the full image, with about the same cells per mL and viability. The video also shows how to save it as a protocol, so every image is counted the same way.

Transcript

So sometimes, when running images through CellCount, not all the corners of the grid will be visible. So I'm uploading an example here. Here we can see the entire 1 mm grid doesn't fit, and it's not perfectly positioned underneath the objective. So in this case, since we're using a microscope camera and the cells actually go all the way from edge to edge of the image, what I would do then, and this is actually much better, is to turn on the full image mode, so it doesn't constrain the counting to the grids. It uses the entire image. And we actually get a larger counted volume. If we look here, we're counting 0.12 microliters. If we go back to counting only the grids, we're at 0.081 microliters. So by using the full image, we actually count more cells, getting a better concentration estimate. And you can see here we still get the same cells per milliliter and the viability as before. So we can click Done. And if you consistently use a microscope camera to do these measurements, then it's a good idea to create a protocol for this. So switching to protocol. Right now, we have no protocol turned on. If I create a new protocol, for example, we can count the whole image. So this will just automatically apply this setting. We can do one image at a time. We want to report with viability. We use a one-to-one dilution with trypan blue, so let's set the dilution factor to two. The default sensitivity, balanced, is fine. Open the camera when the protocol is chosen, that's okay. And then apply the detected grid automatically. And then if we go to this protocol, we can use it, clear the sample and start a new one. So here it'll give you the option to upload a file or use the camera. You'll see it automatically just finds two reference points, uses that to set the scale for the whole image. And it also is nice because you don't have to worry about positioning the slide correctly underneath to get the whole grid in line.

Try it on your own image

The counting page works the way the videos show, on a photo from a phone at the eyepiece or a frame from a camera on the microscope.

Every title, description, transcript and caption file on this page is also at /tutorials.json, for software and AI assistants.